Atari 600XL Field Service Troubleshooting

Year
1983
Type
Component
Category
Atari service procedure: self-test, SuperSALT testing, symptom checklist and the ANTIC tech tip
Manufacturer
Atari, Inc.
Salmon-pink cover of the Atari 600XL Computer Field Service Manual with a large outlined ATARI logo and the number FD100610, Rev. 1, October 1983

Overview

Atari's 600XL Computer Field Service Manual (FD100610, Rev. 1, October 1983) was written for the authorised service centres that repaired XL machines. Section 1, the theory of operation, is summarised in 600XL internals. This page covers the rest of the manual, which is what a technician actually used at the bench. It explains how to test a 600XL with the built-in self-test and the SuperSALT kit, how to go from a symptom to a chip number, a tech tip about factory-fitted wrong ANTIC chips, and how to take the machine apart.

Step 1: the built-in self-test

With no cartridge fitted, hold OPTION while switching on. The self-test menu offers Memory, Audio-Visual, Keyboard and All Tests. SELECT moves the pointer, START runs the chosen test, HELP returns to the menu, and RESET exits to BASIC.

  • Memory test. Two long bars stand for the 600XL's two 8K ROMs, and sixteen blocks stand for its 16K of RAM. Each turns white while it is tested, then light green if good or red if bad. A failed block stays red and isn't tested again.
  • Audio-visual test. A six-note tune plays on each of POKEY's four voices in turn, with the notes shown on a stave. A note without sound, or sound without a note, shows a fault.
  • Keyboard test. Each key flashes in inverse video and beeps, except RESET, HELP and BREAK.

The manual warns that self-test doesn't enter attract mode. A test screen should not be left up for more than about seven minutes, or it may burn into the TV.

Step 2: SuperSALT

For a full check Atari used the CPS SuperSALT kit (FK100331). It has a cartridge (FD100335) and the Extended Hardware box (FA100332). The box connects to both joystick ports (port 1 to its port 4, port 2 to its port 3) and to the SIO port, and needs its own power adaptor. Its tone switch is set away from the controller ports for XL machines and toward them for a 400/800. The Performance Test must be run first. It goes through clock, 6502, ANTIC stress, grey bars, I/O port and voltage, RAM, tone, video, joystick, keyboard and paddle tests, and an error summary then lists the failures.

The manual's remedies for SuperSALT failures include:

  • 6502 test. Some failure types call for replacing the CPU (U10) straight away. Others should first be confirmed with the RAM test.
  • RAM test. Data-bit errors on D0–D3 point to RAM chip U11, and on D4–D7 to U12. Before replacing either, check the ANTIC revision (see the tech tip below).
  • Tone test. A missing tone means POKEY (U20), the sound mixer U8, or the 4.5 MHz sound oscillator. The oscillator may only need adjusting.

Step 3: the symptom checklist

Section 3 lists faults in the order they are usually met:

Symptom Suspects Remedy
Snowy screen Switch box, power supply and switch, channel switch, RF modulator, RF cable Adjust or replace
Black or grey screen 5 V supply (rails +5A, +5B, +5C), crystal Y1 Check all three rails; check Y1 is at 3.58 MHz
Green or yellow screen U1–U7, U11–U16 Repair or replace
Solid blue screen U1, U2, U4 Check the BASIC ROM and its support circuit
No or bad colour U17, U19, Q1, Q6, CR1–2, Y1, U8, colour pot R43, RF modulator or the TV Adjust colour or modulator, or replace
Upside-down characters in the player field U9 (ANTIC) Replace
Some or all keys dead POKEY U20, U22, U23, keyboard, cable Repair or replace
Console keys dead U17 (GTIA), switches, cable Repair or replace
ROM test fails U1–U4 Repair or replace
RAM test fails U1, U2, U5–U7, U11–U16, U18 Check U18 is a 74S32 and ANTIC is the correct revision
CPU test fails Y1, Q2, Q3, U10 Check the 3.58 MHz oscillator
I/O port or joystick/paddle fails U20, U21, Q4, J5, J6 Needs the SuperSALT extended hardware

The note on the RAM-test line matters. The manual says the machine must have the right parts at U18 and ANTIC "or RAM will fail".

The wrong-ANTIC tech tip

A tech tip dated 17 August 1983 is filed at the back of the manual. It says that the first "24 K" international 600XLs (apparently the first 24,000 units, since no 24K model existed), and possibly some US ones, fail SuperSALT's RAM test. It adds that most programs that blank the screen also fail on them. The cause was usually the wrong ANTIC fitted at the factory. The correct part at U9 is C021697 for domestic (NTSC) machines and C021698 for international (PAL) machines. The fix was simply to fit the right chip.

Disassembly

Turn the 600XL over and remove four screws from the base. Turn it upright and lift the left side of the top cover far enough to unplug the keyboard cable. To remove the board, take out the screw reached through the RF shield at top left (a magnetic screwdriver helps), then the remaining four screws. Six nuts and bolts hold the two halves of the shield together.

Using it today

The self-test and the symptom table are still the quickest way into a dead 600XL. If you swap an ANTIC between machines, remember that NTSC and PAL parts differ. Many 600XLs have been upgraded to 64K (see 600XL 64K upgrade), so a machine on your bench may not match the manual's memory layout.

Credits