R-Verter / SupraVerter (SIO-to-RS-232 Modem Adapter)

Year
1984
Type
Interface
Category
SIO-to-RS-232 modem adapter cable
Manufacturer
Advanced Interface Devices (A.I.D.); later Supra Corporation
A.I.D. R-Verter adapter cable with manual and disk

Overview

An Atari 850 or P:R: Connection was the "proper" way to attach an RS-232 modem, but many owners only needed one serial device. The R-Verter Serial Bus Modem Adapter from Advanced Interface Devices (A.I.D.), introduced in 1984, is just a cable with a little circuitry: an Atari SIO plug at one end and a DB-25 male connector for a standard modem at the other. It came with several R: device handlers, so terminal software written for the 850 could use it. Supra later sold it as the SupraVerter and bundled it with the SupraModem 2400. Antic's January 1988 Shoppers Guide described it as converting "the 8-bit Atari's SIO port to an RS-232 port".

Specifications

Item Value
Connection Atari SIO to DB-25P (modem side)
Electronics Level shifting only, no UART
Enable SIO motor-control line
Status lines Carrier Detect to SIO Proceed, Data Set Ready to SIO Interrupt (inverted)
Software Several R: handlers on disk
Limitation Only one motor-line device on the SIO bus at a time

How it works

The R-Verter doesn't use the normal SIO command protocol. When software turns the cassette motor-control line on, the adapter connects the modem's transmit and receive lines to the SIO data lines for full-duplex use and enables DTR sensing. When the motor line is off, the adapter disconnects. Because there's no UART, POKEY generates the serial bit timing, and the R: handler software takes care of parity and stop bits. The modem's Carrier Detect and Data Set Ready signals come back on the SIO Proceed and Interrupt lines, so software can see when a connection is made.

Similar adapters include the Digital Devices U-Call and the British Datatari interface for Prestel-style 1200/75 Viewdata. The motor-line trick means you can't use two such devices, or an R-Verter and another motor-controlled device, on the same SIO chain at once.

Using one today

  • Load the R-Verter R: handler first, then any 850-style terminal program.
  • Keep a program recorder off the chain while the R-Verter is in use, since both depend on the motor line.
  • The R-Verter is still useful for connecting a Hayes-command serial "Wi-Fi modem" directly to an Atari. Several modern Internet-modem projects advertise R-Verter-compatible software for exactly this.

Credits