BOT Engineering Pocket Modem

Year
1984
Type
Peripheral
Category
300-baud SIO modem
Manufacturer
BOT Engineering

Overview

The Pocket Modem from BOT Engineering was one of several small modems that let Atari owners get online without buying an 850 Interface Module. (BOT also made a 64K memory board for the 600XL, which some Canadian 600XLs had fitted at the factory.) It plugs straight into the SIO port, runs at 300 baud, can pulse-dial and auto-answer, and came with terminal software on cartridge or disk written by ADCM Systems. Instead of the normal SIO device protocol, it uses POKEY's serial port directly for data and a home-grown control scheme on two SIO handshake lines. That makes it simple and cheap, but it means software has to know about it specifically.

Specifications

Item Value
Maker BOT Engineering
Speed 300 baud (POKEY can also run it at 110, 210 and 500 baud); a 1200-baud upgrade was offered but apparently not supported by software
Connection SIO; must be the last device on the chain
Control SIO motor line (clock) and command line (data); only one motor-controlled device per system
Dialling Pulse only (no tone)
Answering Ring detect on the SIO interrupt line; software answers after counting rings
Carrier detect SIO proceed line
Software Pocket Modem Software v2.06 / v2.08 by ADCM Systems (1984), cartridge or disk; later disk with an M: modem handler (MDRIVER.REL)

How it works

Data. The modem has no baud-rate setting of its own. Data goes straight through POKEY's serial port in full duplex, so the speed is whatever rate POKEY is programmed for. Supported rates are 110, 210, 300 and 500 baud.

Commands. The modem holds four mode bits:

Bit Function
0 Connect the SIO data lines to the phone line
1 Off-hook (1) / on-hook (0)
2 Originate (0) / answer (1) carrier frequencies
3 Dialling enabled

Software shifts a new mode into the modem one bit at a time: it sets the SIO command line to the bit value and pulses the motor control line as a clock. The standard driver is slow, about one bit every six video frames. Common modes are %0000 (hang up), %0011 (connected, originating), %0111 (connected, answering), %0010 or %0110 (hold the line while using the disk drive), and %1010 (dialling).

Dialling. In dialling mode the command line directly controls the hook switch, and the software pulse-dials by toggling it with the right timing. Tone dialling isn't supported.

Answering and carrier. When the phone rings, the modem pulses the SIO interrupt line. The software counts the pulses and switches to answer mode after enough rings. The proceed line reports carrier: low means no carrier, high means carrier present.

Because it uses the motor line, the Pocket Modem can't share the SIO bus with another motor-controlled device, such as a program recorder or an R-Verter-style adapter in use. It also has to be the last device on the chain.

Software

The original package shipped the Pocket Modem Software (ADCM Systems, 1984) on cartridge. Later packages offered the same intelligent terminal on disk as TERM.OBJ, along with PDRIVE.OBJ and a public-domain MODEM.BAS terminal written in BASIC. A 1985 disk added MDRIVER.REL, an M: device handler, plus a simple terminal that uses it, so other programs could talk to the modem through CIO. General-purpose terminal programs written for the 850's R: handler won't drive it without a specific handler.

Using it today

  • Placement. Put it at the end of the SIO chain, with no cassette deck running at the same time.
  • Phone lines. It needs an analogue line that accepts pulse dialling. If yours doesn't, dial from a telephone on the same line and then switch the modem online.
  • Emulation. Altirra emulates the Pocket Modem, which is the easiest way to try the original terminal software.

Compatibility

All Atari 400/800/XL/XE computers via SIO. It works with its own terminal software and programs that use the M: handler or drive the hardware directly. It isn't compatible with software that expects an 850 R: device or a Hayes-command modem.

Credits